Intraoperative vector flow imaging of the heart

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Standard

Intraoperative vector flow imaging of the heart. / Hansen, Kristoffer Lindskov; Moller-Sorensen, Hasse; Pedersen, Mads Moller; Kjaergaard, Jesper; Nilsson, Jens Christian; Lund, Jens Teglgaard; Nielsen, Michael Bachmann; Jensen, Jorgen Arendt.

2013 IEEE International Ultrasonics Symposium, IUS 2013. 2013. p. 1745-1748 6725113 (IEEE International Ultrasonics Symposium, IUS).

Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

Harvard

Hansen, KL, Moller-Sorensen, H, Pedersen, MM, Kjaergaard, J, Nilsson, JC, Lund, JT, Nielsen, MB & Jensen, JA 2013, Intraoperative vector flow imaging of the heart. in 2013 IEEE International Ultrasonics Symposium, IUS 2013., 6725113, IEEE International Ultrasonics Symposium, IUS, pp. 1745-1748, 2013 IEEE International Ultrasonics Symposium, IUS 2013, Prague, Czech Republic, 21/07/2013. https://doi.org/10.1109/ULTSYM.2013.0445

APA

Hansen, K. L., Moller-Sorensen, H., Pedersen, M. M., Kjaergaard, J., Nilsson, J. C., Lund, J. T., Nielsen, M. B., & Jensen, J. A. (2013). Intraoperative vector flow imaging of the heart. In 2013 IEEE International Ultrasonics Symposium, IUS 2013 (pp. 1745-1748). [6725113] IEEE International Ultrasonics Symposium, IUS https://doi.org/10.1109/ULTSYM.2013.0445

Vancouver

Hansen KL, Moller-Sorensen H, Pedersen MM, Kjaergaard J, Nilsson JC, Lund JT et al. Intraoperative vector flow imaging of the heart. In 2013 IEEE International Ultrasonics Symposium, IUS 2013. 2013. p. 1745-1748. 6725113. (IEEE International Ultrasonics Symposium, IUS). https://doi.org/10.1109/ULTSYM.2013.0445

Author

Hansen, Kristoffer Lindskov ; Moller-Sorensen, Hasse ; Pedersen, Mads Moller ; Kjaergaard, Jesper ; Nilsson, Jens Christian ; Lund, Jens Teglgaard ; Nielsen, Michael Bachmann ; Jensen, Jorgen Arendt. / Intraoperative vector flow imaging of the heart. 2013 IEEE International Ultrasonics Symposium, IUS 2013. 2013. pp. 1745-1748 (IEEE International Ultrasonics Symposium, IUS).

Bibtex

@inproceedings{19743db94a534af2a834871b22a87304,
title = "Intraoperative vector flow imaging of the heart",
abstract = "The cardiac flow is complex and multidirectional, and difficult to measure with conventional Doppler ultrasound (US) methods due to the one-dimensional and angle-dependent velocity estimation. The vector velocity method Transverse Oscillation (TO) has been proposed as a solution to this. TO is implemented on a conventional US scanner (Pro Focus 2202 UltraView, BK Medical) using a linear transducer (8670, BK Medical) and can provide real-time, angle-independent vector velocity estimates of the cardiac blood flow. During cardiac surgery, epicardiac US examinations using TO were performed on three patients. Antegrade central jet and retrograde flow near the vessel wall in the ascending aorta and the pulmonary artery were seen during systole, while stable vortices were seen in the aortic sinuses and complex flow patterns were seen around the valves during diastole. In the right atrium, a stable vortex was seen during the entire heart cycle. For comparison, simultaneous measurements were obtained with conventional spectral Doppler (SD) and intravenous catheter thermodilution technique (TD). Peak systolic velocities were underestimated by 18% compared to SD and cardiac output was underestimated by 16% compared to TD. This is the first time TO measurements have been obtained of cardiac flow. TO can potentially reveal new information of cardiovascular physiology and blood flow dynamics, and become a valuable tool in cardiology.",
keywords = "Blood flow, Cardiology, Intraoperative ultrasound, Transverse Oscillation, Vector velocity estimation",
author = "Hansen, {Kristoffer Lindskov} and Hasse Moller-Sorensen and Pedersen, {Mads Moller} and Jesper Kjaergaard and Nilsson, {Jens Christian} and Lund, {Jens Teglgaard} and Nielsen, {Michael Bachmann} and Jensen, {Jorgen Arendt}",
year = "2013",
doi = "10.1109/ULTSYM.2013.0445",
language = "English",
isbn = "9781467356862",
series = "IEEE International Ultrasonics Symposium, IUS",
publisher = "Institute of Electrical and Electronics Engineers",
pages = "1745--1748",
booktitle = "2013 IEEE International Ultrasonics Symposium, IUS 2013",
note = "2013 IEEE International Ultrasonics Symposium, IUS 2013 ; Conference date: 21-07-2013 Through 25-07-2013",

}

RIS

TY - GEN

T1 - Intraoperative vector flow imaging of the heart

AU - Hansen, Kristoffer Lindskov

AU - Moller-Sorensen, Hasse

AU - Pedersen, Mads Moller

AU - Kjaergaard, Jesper

AU - Nilsson, Jens Christian

AU - Lund, Jens Teglgaard

AU - Nielsen, Michael Bachmann

AU - Jensen, Jorgen Arendt

PY - 2013

Y1 - 2013

N2 - The cardiac flow is complex and multidirectional, and difficult to measure with conventional Doppler ultrasound (US) methods due to the one-dimensional and angle-dependent velocity estimation. The vector velocity method Transverse Oscillation (TO) has been proposed as a solution to this. TO is implemented on a conventional US scanner (Pro Focus 2202 UltraView, BK Medical) using a linear transducer (8670, BK Medical) and can provide real-time, angle-independent vector velocity estimates of the cardiac blood flow. During cardiac surgery, epicardiac US examinations using TO were performed on three patients. Antegrade central jet and retrograde flow near the vessel wall in the ascending aorta and the pulmonary artery were seen during systole, while stable vortices were seen in the aortic sinuses and complex flow patterns were seen around the valves during diastole. In the right atrium, a stable vortex was seen during the entire heart cycle. For comparison, simultaneous measurements were obtained with conventional spectral Doppler (SD) and intravenous catheter thermodilution technique (TD). Peak systolic velocities were underestimated by 18% compared to SD and cardiac output was underestimated by 16% compared to TD. This is the first time TO measurements have been obtained of cardiac flow. TO can potentially reveal new information of cardiovascular physiology and blood flow dynamics, and become a valuable tool in cardiology.

AB - The cardiac flow is complex and multidirectional, and difficult to measure with conventional Doppler ultrasound (US) methods due to the one-dimensional and angle-dependent velocity estimation. The vector velocity method Transverse Oscillation (TO) has been proposed as a solution to this. TO is implemented on a conventional US scanner (Pro Focus 2202 UltraView, BK Medical) using a linear transducer (8670, BK Medical) and can provide real-time, angle-independent vector velocity estimates of the cardiac blood flow. During cardiac surgery, epicardiac US examinations using TO were performed on three patients. Antegrade central jet and retrograde flow near the vessel wall in the ascending aorta and the pulmonary artery were seen during systole, while stable vortices were seen in the aortic sinuses and complex flow patterns were seen around the valves during diastole. In the right atrium, a stable vortex was seen during the entire heart cycle. For comparison, simultaneous measurements were obtained with conventional spectral Doppler (SD) and intravenous catheter thermodilution technique (TD). Peak systolic velocities were underestimated by 18% compared to SD and cardiac output was underestimated by 16% compared to TD. This is the first time TO measurements have been obtained of cardiac flow. TO can potentially reveal new information of cardiovascular physiology and blood flow dynamics, and become a valuable tool in cardiology.

KW - Blood flow

KW - Cardiology

KW - Intraoperative ultrasound

KW - Transverse Oscillation

KW - Vector velocity estimation

UR - http://www.scopus.com/inward/record.url?scp=84894375094&partnerID=8YFLogxK

U2 - 10.1109/ULTSYM.2013.0445

DO - 10.1109/ULTSYM.2013.0445

M3 - Article in proceedings

AN - SCOPUS:84894375094

SN - 9781467356862

T3 - IEEE International Ultrasonics Symposium, IUS

SP - 1745

EP - 1748

BT - 2013 IEEE International Ultrasonics Symposium, IUS 2013

T2 - 2013 IEEE International Ultrasonics Symposium, IUS 2013

Y2 - 21 July 2013 through 25 July 2013

ER -

ID: 331501826