Validity of continuous glucose monitoring for categorizing glycemic responses to diet: implications for use in personalized nutrition.

Research output: Contribution to journalJournal articleResearchpeer-review

  • Merino Ribas, Jordi
  • I Linenberg
  • KM Bermingham
  • S Ganesh
  • E Bakker
  • LM Delahanty
  • Andrew Chan
  • Pujol J Capdevila
  • Jonathan Wolf
  • Khatib H Al
  • PW Franks
  • TD Spector
  • Jose Ordovas
  • Sarah Berry
  • Ana M. Valdes
BackgroundContinuous glucose monitor (CGM) devices enable characterization of individuals' glycemic variation. However, there are concerns about their reliability for categorizing glycemic responses to foods that would limit their potential application in personalized nutrition recommendations.ObjectivesWe aimed to evaluate the concordance of 2 simultaneously worn CGM devices in measuring postprandial glycemic responses.MethodsWithin ZOE PREDICT (Personalised Responses to Dietary Composition Trial) 1, 394 participants wore 2 CGM devices simultaneously [n = 360 participants with 2 Abbott Freestyle Libre Pro (FSL) devices; n = 34 participants with both FSL and Dexcom G6] for ≤14 d while consuming standardized (n = 4457) and ad libitum (n = 5738) meals. We examined the CV and correlation of the incremental area under the glucose curve at 2 h (glucoseiAUC0-2 h). Within-subject meal ranking was assessed using Kendall τ rank correlation. Concordance between paired devices in time in range according to the American Diabetes Association cutoffs (TIRADA) and glucose variability (glucose CV) was also investigated.ResultsThe CV of glucoseiAUC0-2 h for standardized meals was 3.7% (IQR: 1.7%-7.1%) for intrabrand device and 12.5% (IQR: 5.1%-24.8%) for interbrand device comparisons. Similar estimates were observed for ad libitum meals, with intrabrand and interbrand device CVs of glucoseiAUC0-2 h of 4.1% (IQR: 1.8%-7.1%) and 16.6% (IQR: 5.5%-30.7%), respectively. Kendall τ rank correlation showed glucoseiAUC0-2h-derived meal rankings were agreeable between paired CGM devices (intrabrand: 0.9; IQR: 0.8-0.9; interbrand: 0.7; IQR: 0.5-0.8). Paired CGMs also showed strong concordance for TIRADA with a intrabrand device CV of 4.8% (IQR: 1.9%-9.8%) and an interbrand device CV of 3.2% (IQR: 1.1%-6.2%).ConclusionsOur data demonstrate strong concordance of CGM devices in monitoring glycemic responses and suggest their potential use in personalized nutrition.This trial was registered at clinicaltrials.gov as NCT03479866.
Original languageEnglish
Book seriesThe American journal of clinical nutrition
Volume115
Issue number6
Pages (from-to)1569-1576
ISSN0002-9165
DOIs
Publication statusPublished - 2022